The Connecticut Department of Public Health (DPH) reminds nutmeggers to be careful when using gas powered generators during the power outage.

Residents are warned of the dangers of carbon monoxide (CO) associated with alternate power sources.

“Carbon monoxide poisoning is a very real danger when using gasoline-powered generators,” DPH officials said. “It’s very important that residents take precautions and properly use gasoline-powered generators and other combustion devices, like stoves and fireplaces, to prevent carbon monoxide poisoning.”

Find out what's happening in Orangewith free, real-time updates from Patch.

The number of deaths from CO poisoning has been rising every year. Between 1996-2006, 334 people died nationally from generator-related CO poisonings, many after major storms knocked out power. In the past few days many families across the state have been pulled out of thier homes due to improperly used generators.

Exhaust from portable generators contains carbon monoxide and generators should never be used indoors or in enclosed spaces such as garages, basements, or porches. Always run the generator outdoors as far from the house as possible, away from doors, windows, and air intake vents. In addition, CO detectors should be installed in homes, especially near sleeping areas.

Find out what's happening in Orangewith free, real-time updates from Patch.

“Proper placement of the generator is critical," health officials said. “A generator located in any enclosed space can kill you. While generators can be very useful during a power outage, it is important that people are aware of how dangerous these generators can be and the proper ways to use them.”

In addition, a licensed electrician should properly wire and connect home-use generators. You may also need a town permit or official inspection for the generator. Before using a portable generator, you must disconnect your home’s electric wiring from the power grid. Otherwise, power from the generator can go out over the utility lines, endangering the lives of workers making repairs.

CO is an invisible, odorless gas that can be fatal. The symptoms of CO poisoning mimic those of the flu, including headache, fatigue, dizziness, nausea, vomiting, or loss of consciousness. If several members of a household experience these symptoms when they are home, but feel better when they are away from the home, there may be a CO problem.

Every home in which a portable generator is operating, or that burns oil, natural gas, wood or coal, should have a carbon monoxide detector that is in good, working order. If the alarm goes off, get out of the house immediately. Call 911 or the town fire department from a cellular phone or neighbor’s house.

DPH offers safety tips to prevent CO poisoning when using gasoline generators and other gasoline-powered equipment.

Safety Tips to Prevent CO Poisoning

• Never use portable generators, pressure washer engines, or other gasoline-powered equipment (including tools) inside your home, garage, carport, basement or other enclosed spaces.

• Place gasoline-powered equipment outside and away from doors, windows or air intake vents.

• Install a CO detector on each floor of your residence near sleeping areas. An Underwriters Laboratory (UL) certified plug-in detector with battery-backup and a digital readout is recommended. Test alarms monthly. Change the battery at least twice a year. Replace alarms every 5 years because the sensors degrade over time.

• Use grilling apparatus such as charcoal or gas grills outdoors only.

**Opening windows and doors, and operating fans is not sufficient to prevent buildup of CO in a home.

• Get out of the house and seek medical help immediately if you or a family member has symptoms of CO poisoning. Symptoms include headache, fatigue, dizziness, nausea or vomiting, and loss of consciousness.

• Call 911 from a cellular phone or neighbor’s home and the Connecticut Poison Control Center at the University of Connecticut Health Center (1-800-222-1222).

For more information on carbon monoxide poisoning and prevention:

• DPH Environmental & Occupational Health Assessment Program

www.ct.gov/dph/com   860-509-7742

• DPH Carbon Monoxide Hazards During Power Outages

http://www.ct.gov/dph/lib/dph/environmental_health/eoha/pdf/co_disasters.pdf

• Consumer Product Safety Commission

www.cpsc.gov

For more information on carbon monoxide detectors:

• Underwriters Laboratories, Inc. www.ul.com

To contact the Department of Public Health, visit its website at www.ct.gov/dph or call (860) 509-7270.

Related Topics: Carbon Monoxide and Public Health


Get more local news delivered straight to your inbox. Sign up for free Patch newsletters and alerts.

We’ve removed the ability to reply as we work to make improvements. Learn more here

To request removal of your name from an arrest report, submit these required items to arrestreports@patch.com.